General Information:
Name and address of the manufacturer
Name: Suzhou South Large Battery Co., Ltd
Address: No. 16, Loushang Rd, East Jinling Rd, Weiting Town, Suzhou Industrial Park
Category: Portable non-rechargeable alkaline battery & dry battery
Product Name 1: Alkaline Manganese Dioxide-Zinc Battery
Common Name: Alkaline Battery
Model: LR03, LR6, LR14, LR20, 6LR61, LR1
Nominal Capacity: LR03(1.5V/1200mah), LR6(1.5V/2500mah), LR14(1.5V/5900mah), LR20(1.5V/9800mah), 6LR61(9V/620mah), LR1(1.5V/600mah)
Product Name 2: Carbon-Zinc Battery
Common Name: Dry Battery
Model: R03, R6P, R14P, R20P, 6F22, 4R25
Nominal Capacity: LR03(1.5V/300mah), R6P(1.5V/700mah), R14P(1.5V/1400mah), R20(1.5V/2500mah), 6R22(9V/200mah), 4R25(6V/7000mah)
Material:
Alkaline battery: Manganese Dioxide (MnO2), Zinc (Zn), Potassium Hydroxide (KOH), Iron, Graphite, copper, water.
Carbon zinc battery: Manganese Dioxide (MnO2), Zinc (Zn), Carbon Rod, Acetylene Black, Zinc Chloride, Ammonium Chloride, Paper, Iron, Graphite, Asphalt Water.
Content of hazardous substances: Mercury free, Cadmium free, lead free.
Related Laws, regulations, Standards:
EU Battery Regulation 2023/1542, EC REACH Regulation (EC 1907/2006), PPWR(EU 2025/40). RoHS 2.0, IEC60086-1,2,3.
Suitable extinguishing media: Carbon dioxide, foam, dry chemical powder.
Guide for use
Installation:
Before inserting batteries into the battery compartment of the equipment, the contacts of both equipment and batteries should be checked for cleanliness and correct positioning. If necessary, clean with a damp cloth and dry before inserting.
It is of extreme importance that batteries are inserted correctly with regard to polarity (+ and -). Follow equipment instructions carefully and use the recommended batteries. Failure to follow
the instructions, which should be available with the equipment, can result in malfunction and damage of the equipment and/or batteries.
Use:
It is not good practice to use or leave equipment exposed to extreme conditions, for example
radiators, or cars parked in the sun, etc.
It is advantageous to remove batteries immediately from equipment which has ceased to function satisfactorily, or when not in use for a long period (e.g. cameras, photoflash, etc.).
Be sure to switch off the equipment after use.
Store batteries in a cool, dry place and out of direct sunlight.
Replacement
Replace all batteries of a set at the same time. Newly purchased batteries should not be mixed with partially exhausted ones. Batteries of different electrochemical systems, grades or brands should not be mixed. Failure to observe these precautions may result in some batteries in a set being driven beyond their normal exhaustion point and thus increase the probability of leakage.
Disposal
Primary batteries may be disposed of via the communal refuse arrangements, provided no
contrary local legal requirements exist. Refer to IEC 60086-5 for further details.